Description
Five temperatures from the first start-up — PRD3 in the complete measurement set
If you know that one thermometer is not enough, this option saves you the step of assembling the set of sensors. You receive PRD3 and five STANDARD probes, so you can immediately build a detailed picture of the process.
You do not start with one measurement and then purchase additional sensors later
From the first start-up, this set uses the controller’s full number of measurement inputs.
5 × STANDARD
Each probe has a 2 m cable and a 50 mm measuring section.
5 process roles
You install each probe for a specific role, and the controller remembers it by its ROM address.
Custom names
You can name the measurement points according to how they are described in your installation.
Separate calibration
Each of the five channels has its own MULTIPLIER and CORRECTION.
You do not have to buy a different controller for each process
PRD3 changes the way it operates depending on the selected application. It is not just a thermostat with more sockets.
DISTILLATION
Full power control, alarms for up to five probes and process outputs. You can work manually or automatically according to temperature.
SMOKING
Three consecutive stages: heating, drying and smoking. Each stage has its own temperature and duration.
BREWING
A simple process based on temperature and time — without building a separate controller for a single task.
BREWERY
A multistage mode for processes requiring successive temperatures and durations.
You choose whether the controller should execute commands or select the power itself
Depending on the process, you can start with simple MANUAL control and later switch to automatic regulation.
MANUAL
You set the power yourself. A probe is not required, and the safety interlocks remain active.
AUTO P
A practical proportional mode. For smoking, the guide recommends it as the starting mode.
AUTO PI
Regulation with an integral term. For distillation, it may be the natural next step after AUTO P.
AUTO PID
An advanced mode available when you want to fine-tune the behaviour of the thermal system.
Instead of a single measurement, you can see the process at several points
PRD3 stores probe roles by their ROM addresses. The five RJ45 sockets are connected in parallel — the probe function does not depend on the socket number.
Custom probe names
You can describe temperatures using names that match your installation, so the screen speaks the language of your process.
An alarm for every probe
Each measurement can have its own thresholds and responses. When an alarm is active, the screen shows which probe triggered it.
Calibration of every channel
For each of the five probes, the controller stores a MULTIPLIER and an OFFSET.
You move a probe between sockets
After correct installation, its role remains the same because PRD3 recognises the sensor's unique address.
PRD3 can do more than just regulate the heater
Additional outputs can work with valves and other process components. Their number and voltage depend on the selected variant.
Process valves
An output can be linked to a selected probe, temperature thresholds and process-dependent durations.
12 V or 230 V
The available additional-output variants are 12 V DC \/ 1 A and 230 V AC \/ 1 A.
Up to 3 outputs
Depending on the configuration, you can choose two or three additional outputs.
Manual or AUTO
In addition to automatic operation, the outputs can also be forced manually in accordance with the controller settings.
The controller can operate independently, while the computer is an optional extra
Choose the USB version only if you want to use communication with a computer.
PAMEL Smoke
Selected USB-B units can work with the PAMEL Smoke application.
Service programs
USB is also used for PAMEL_BUS_AT communication with service tools.
The process does not depend on a PC
A computer connection is not required for the controller to run the process independently.
Because five probes turn PRD3 from a controller into a process measurement centre
During distillation, you can monitor several points in the column or installation. During smoking, you can control the chamber and additional process locations. In a brewery and other thermal processes, several measurements provide a much more complete picture than a single thermometer.
Most importantly: you do not need to assemble the probes separately — all five are already included in this offer.
Choose the configuration for your installation — without guessing what is included as standard
Set ready for operation with complete measurement capability
| Probes included in the set | 5 × STANDARD, each with: 2 m cable and 50 mm measuring section. |
|---|---|
| Process modes | DISTILLATION / FOOD SMOKING / BREWING / BREWERY. |
| Power modes | MANUAL \/ AUTO P \/ AUTO PI \/ AUTO PID. |
| Food smoking | heating → drying → smoking. |
| Additional outputs | OUT1–OUT3; 12 V or 230 V / 1 A variant, depending on the configuration. |
| USB | Optional USB-B +50 PLN. |
| Power control | phase-controlled or group-controlled. |
PRD3 Product Centre
Instructions, FAQs, materials and available software for the PRD3 family are collected in the Product Centre. You start with your model instead of searching for information across the entire website.
OPEN THE PRD3 PRODUCT CENTRE ↗