Description
More than just a heater. Five temperatures, processes, alarms and additional outputs in one controller.
PRD3 starts to make sense exactly where a simple thermostat is no longer enough. You can control the heater power, monitor up to five temperatures, carry out smoking in stages, control distillation, brewing or a brewery process, and use the additional outputs for valves and other process components.
You do not have to buy a different controller for each process
PRD3 changes the way it operates depending on the selected application. It is not just a thermostat with more sockets.
DISTILLATION
Full power control, alarms for up to five probes and process outputs. You can work manually or automatically according to temperature.
SMOKING
Three consecutive stages: heating, drying and smoking. Each stage has its own temperature and duration.
BREWING
A simple process based on temperature and time — without building a separate controller for a single task.
BREWERY
A multistage mode for processes requiring successive temperatures and durations.
You choose whether the controller should execute commands or select the power itself
Depending on the process, you can start with simple MANUAL control and later switch to automatic regulation.
MANUAL
You set the power yourself. A probe is not required, and the safety interlocks remain active.
AUTO P
A practical proportional mode. For smoking, the guide recommends it as the starting mode.
AUTO PI
Regulation with an integral term. For distillation, it may be the natural next step after AUTO P.
AUTO PID
An advanced mode available when you want to fine-tune the behaviour of the thermal system.
Instead of a single measurement, you can see the process at several points
PRD3 stores probe roles by their ROM addresses. The five RJ45 sockets are connected in parallel — the probe function does not depend on the socket number.
Custom probe names
You can describe temperatures using names that match your installation, so the screen speaks the language of your process.
An alarm for every probe
Each measurement can have its own thresholds and responses. When an alarm is active, the screen shows which probe triggered it.
Calibration of every channel
For each of the five probes, the controller stores a MULTIPLIER and an OFFSET.
You move a probe between sockets
After correct installation, its role remains the same because PRD3 recognises the sensor's unique address.
PRD3 can do more than just regulate the heater
Additional outputs can work with valves and other process components. Their number and voltage depend on the selected variant.
Process valves
An output can be linked to a selected probe, temperature thresholds and process-dependent durations.
12 V or 230 V
The available additional-output variants are 12 V DC \/ 1 A and 230 V AC \/ 1 A.
Up to 3 outputs
Depending on the configuration, you can choose two or three additional outputs.
Manual or AUTO
In addition to automatic operation, the outputs can also be forced manually in accordance with the controller settings.
The controller can operate independently, while the computer is an optional extra
Choose the USB version only if you want to use communication with a computer.
PAMEL Smoke
Selected USB-B units can work with the PAMEL Smoke application.
Service programs
USB is also used for PAMEL_BUS_AT communication with service tools.
The process does not depend on a PC
A computer connection is not required for the controller to run the process independently.
One panel instead of several separate controllers
In a simpler setup, you monitor power, temperatures, alarms and valves separately. PRD3 brings these tasks together in one place.
This is especially convenient when the process expands over time: you start with a heater and one probe, then add further measurements or actuating components without replacing the controller.
Choose the configuration for your installation — without guessing what is included as standard
PRD3 parameters — without old functions the device does not have
| Power supply | 230 V \/ 50 Hz; 1F version. |
|---|---|
| Power path | offered up to 5,5 kW; the manual specifies a maximum of 25 A for the power path, and the entire system is also limited by the cables, plugs, sockets, protective devices and installation. |
| Probes | max. 5 × DS18B20, RJ45 sockets on a shared bus. |
| Power modes | MANUAL \/ AUTO P \/ AUTO PI \/ AUTO PID. |
| Power control | phase-based or group-based; a restart is required after changing the control method. |
| Power step | set in the menu; range 0,125–10,000%. |
| Process modes | DISTILLATION / FOOD SMOKING / BREWING / BREWERY. |
| Food smoking | 3 stages: heating → drying → food smoking. |
| Additional outputs | OUT1–OUT3, 12 V DC / 1 A or 230 V AC / 1 A, depending on the variant. |
| USB | Optional USB-B; communication with PAMEL Smoke and service tools. |
PRD3 Product Centre
Instructions, FAQs, materials and available software for the PRD3 family are collected in the Product Centre. You start with your model instead of searching for information across the entire website.
OPEN THE PRD3 PRODUCT CENTRE ↗

























