Description
Set the temperature. PRT1 will decide when to switch heating or cooling on.
PRT1 is for people who do not need an advanced process controller. Connect a heater, fan or cooling device to the PRT1 socket, place the probe where you want to measure the temperature, set the value and you are ready to go.
For normal operation, you only need to set one temperature
PRT1 can have calibration and adjustable hysteresis, but you do not need to enter the advanced settings for everyday use.
1. Place the probe
Place or mount the sensor where you actually want to control the temperature.
2. Connect the device
Connect the heating or cooling device to the PRT1 socket.
3. Set the temperature
Use the + and - buttons to select the setpoint.
4. PRT1 switches the output
The controller compares the setpoint with the measured temperature and switches the socket on or off.
The same thermostat can operate in two opposite directions
In the settings, you choose 0 or 1.
0 mode — HEATING
When the temperature is too low, PRT1 switches on the heating device. Once the condition resulting from the setpoint and hysteresis is reached, it switches it off.
1 mode — COOLING
When the temperature is too high, PRT1 switches on the cooling device or fan. Once the temperature has cooled down, the output is switched off.
Dot = output ON
A dot on the display indicates that the socket supplying the device is currently powered.
The setpoint is saved in memory
If the power fails, the last set temperature is not lost.
Measure where the temperature matters — not just next to the socket
This is the key advantage of this version over a thermostat with an internal sensor.
Process temperature
You can place the probe at a selected point in the chamber or space whose conditions you are controlling.
The controller can be farther away
PRT1 stays by the socket, while you route the sensor cable to the measurement point.
Do not judge by another location
The difference compared with a second thermometer is often due to a different position, not a sensor error.
Do not pull the cable
The probe and cable should be routed without sharp bends or mechanical strain.
Do not let the device switch every few seconds
Hysteresis determines how large a temperature change is needed before PRT1 changes the output state. The range is 0,0–9,5°C, and the increment is 0,5°C.
The factory starting point is 0,5°C. A larger hysteresis limits the switching frequency, but at the same time increases the permissible temperature fluctuation.
This is particularly important for cooling devices, fans and loads that should not be switched too often.
PRT1 does not overwhelm you with information
Most of the time, the screen shows the set temperature.
Set temperature
This is the main screen and the value you change with + / -.
Current temperature
Every several seconds, the actual probe measurement appears for approximately 2 seconds.
Dot
It indicates that the output is switched on and the device is receiving voltage.
„88”
It appears only while entering the successive stages of the advanced settings.
First compare the sensors side by side
The instructions emphasize that the device is factory-calibrated and that corrections are usually unnecessary.
Correction A
Constant shift of the reading: range -5…+5°C, increment 1°C.
Correction B
Changes the characteristic slope when the error increases with temperature. Increment 0,05; default value 1,25.
Stabilize first
Compare the two thermometers in the same place, and only after the readings have stabilized.
Do not calibrate a location difference
A probe next to a heater and a thermometer by the door may correctly show different temperatures.
In a simple setup where one measurement is to control one device
You do not need a multistage program or power control — only automatic ON/OFF based on temperature.
Electric heater
PRT1 can switch on the heating when the temperature falls below the operating condition.
Fan
In cooling mode, it can start ventilation when the temperature is exceeded.
Cooling device
1 mode operates in the opposite direction to heating.
Simple chambers and workstations
The external probe allows you to measure at a location away from the controller socket.
If temperature is to make the decision, choose PRT1. If time is the deciding factor — PT1.
Both devices are socket-mounted and easy to operate, but they solve completely different tasks.
PRT1 — temperature control
The probe measures the temperature, and the thermostat switches the device on and off to maintain the conditions resulting from the setpoint and hysteresis.
PT1 — time control
The timer does not measure temperature. It switches the device on and off according to a time, delay or cycle.
PRT1 controls temperature by switching the socket
This is a classic thermostat: the device is on or off. PRT1 does not smoothly reduce heater power to 40% or 15%.
If you need smooth power regulation, a multi-stage program or advanced process automation, a different type of controller PAMEL will be a better choice. PRT1 is deliberately simple.
Version offered on this listing: external probe and load up to 5,5 kW
| Power supply | 230 V, -20% / +10%, 50 Hz. |
|---|---|
| Setting range | -9…+99°C. |
| Modes | 0 = heating, 1 = cooling. |
| Hysteresis | 0,0–9,5°C, increment 0,5°C; default 0,5°C. |
| Maximum load for this listing | up to 5,5 kW; the marking on the specific unit applies. |
| Probe | external, cable approx. 1,8 m. |
| Correction A | -5…+5°C, increment 1°C. |
| Correction B | increment 0,05; default value 1,25. |
| Power consumption | max. 0,2 W. |
| Dimensions | approx. 80 × 60 × 60 mm. |
| Protection rating | IP20. |
Power in kW is not everything
The PRT1 manual does not recommend large inductive loads. With compressors, large motors and other loads with high starting current, you must take the load characteristics into account, not just its rated power.
PRT1 has an IP20 protection rating and is intended for operation in a dry room.